Super Span X

Simplify your construction process.

This PBR-panel is a popular roof and wall panel that's used in a wide variety of commerical, industrial, agricultural, and architectural applications.

Super-Span.jpg

Super Span X Product Brochure

Why choose Super Span X

The profile of the Super Span X makes it very strong, allowing for greater distances between support members, reducing costs and speeding up installation. This panel has a purlin-bearing leg that provides support to the bottom of the panel when installing lap fasteners.

When to use Super Span X

Super Span X is by far our most popular profile, blending a profile that's aesthetically pleasing that can also handle larger spans. This panel works well with any kind of project.

Super Span X is easy to install and can shorten and simplify your construction process. Choose Super Span X from Whirlwind and you'll be sure to receive your order quickly, on time, and undamaged.

Super Span X features

Coverage Width 36"
Rib Spacing 12"
Rib Height 1-1/4"
Minimum Slope 1/2:12
Panel Attachment Exposed Fastening System
Gauge 22, 24 and 26 GA
Coatings Galvalume Plus®, SMP, Kynar

Additional specifications

  • UL 580 Up-Lift Tested, Class 90 Rated
  • UL 2218 Hail Impact Resistant
  • Inclined: Unlimited
  • Impact: Class 4
  • Florida Product Approval FL# 17700 and 17702
  • Texas Department of Insurance Report RC-186 and RC-480
SUPER SPAN X DESIGN PROPERTIES
      Top In Compression Bottom In Compression
GAUSE/
THICKNESS
Fy
(KSI)
WEIGHT
(PSF)
Ix
(In4-Ft)
Ma
(In-Kip)
Ix
(In4-Ft)
Ma
(In-Kip)
26 (t=.0170") 80* 0.83 0.0370 1.2697 0.0323 1.6610
26 (t=.0176") 80* 0.86 0.0380 1.4057 0.0337 1.7230
24 50 1.09 0.0570 1.7500 0.0467 1.8633

* Fy is 80-ksi reduced to 60-ksi in accordance with the 2007 edition of the North American Specification for Design For Design of Cold-Formed Steel Structural Members – A2.3.2

NOTES

  1. All section properties are calculated in accordance with the 2007 edition of the North American Specification for Design For Design of Cold-Formed Steel Structural Members.
  2. Ix is for deflection determination.
  3. Mx is allowable bending movement.

Request a quote now on Super Span X or other roofing or siding components from Whirlwind.